SINGLE LAYER PLASTERBOARD
PARTITIONS FIRE RATED

Fire-rated plasterboard partitions - Single layer wall system with shadow head and skirting details

Tested – 33 MINUTES INTEGRITY AND 33 MINUTES INSULATION

75mm solid module construction

75mm solid module using 50mm vertical stud, plaster shadow head trim (code SA13) and skirting (code SA14) with taped and filled plasterboard joints.

SA Solutions’ Seamless Abutments single layer plasterboard partition system is a solid module with an overall thickness of 75mm. The construction uses SA Solutions 50mm galvanised steel stud (code 853), U-channel head and base track (code 835), and horizontal fixing strap (code DM53GF1), fixed to the supporting structure at 600mm centres.

Studs, board joints and cavity insulation

The vertical studs are cut a nominal 18mm short of the floor-to-ceiling height and positioned at 600mm centres. A single skin of 12.5mm thick taper edge plasterboard is screw fixed to each side using BZP finished 25mm long drywall screws (code SA319) at 300mm centres.

The vertical board joints are taped and wet plaster filled across the butt joint taper section of the plasterboards to mask the screw fixings. The partition cavity is filled with SA Solutions’ 60mm thick Crown factory clad (code 880).

Head shadow trim and skirting detail

The Seamless Abutments head shadow trim (code SA13) and skirting (code SA14) plaster mouldings are screw fixed using BZP finished 25mm long drywall screws (code SA319) at 300mm centres to the U-channel head and base track (code 835) and fixing strap (code DM53GF1).

The horizontal joints between the plasterboard and plaster mouldings are then taped and wet plaster filled across the butt joint section.

Acoustic, thermal and project-specific requirements

The system includes insulation board as part of the tested construction. Any acoustic, thermal or project-specific performance requirements should be checked against the relevant specification, supporting test evidence and project design requirements.

THE CONSTRUCTION HAS BEEN TESTED IN ACCORDANCE WITH:

Fire rated plasterboard wall construction detail
Single layer fire rated plasterboard partitions installed in a commercial project

Build it as tested

The Seamless Abutments single layer plasterboard partition system must be constructed with intumescent mastic at the abutments.

Foams and intumescent seals

It is important that the type, size and fitting detail for the foams and intumescent seals remain as tested. These products can exhibit significantly different characteristics, which may alter the fire performance achieved during the test. They must not be considered interchangeable, even where an individual product has been tested separately or where the dimensions appear to be maintained.

Acoustic, thermal and project-specific requirements

The system includes insulation board as part of the tested construction. Any acoustic, thermal or project-specific performance requirements should be checked against the relevant specification, supporting test evidence and project design requirements.

Seamless abutment joint detail for single layer fire rated plasterboard partition

If you have any questions or can not see what you are looking for, please do not hesitate to contact us, we provide bespoke solutions across our range of products. Click below to live chat or send us a message.

You can also call us on

Contact Us Today

Got a question? Need advice?

Tony our Design Specialist is online and ready to help.

You can email drawings  and we will get back to you fast – no bots or botty (as we call him) – just a hot-line to real answers!

Connect with Tony on Linkedin

tony baccarini

We'll get in touch at your convenience

Send us a message and we'll be in touch soon!